Safety Lighting in Places of Assembly
Does your Theatre meet Life Safety code? If not upgrade your aisle lighting system and step lighting systems. Even though your facility may have passed code when it was built, you can still be a victim of a personal injury lawsuit. We are in an era of ever increasing litigation of personal injury lawsuits. Attorneys are completely educated in the use of light meters, digital cameras and the N.F.P.A. (life safety code)

Careful consideration must be given to the importance of proving sufficient lighting in places of assembly to comply with the N.F.P.A.( life safety code) the code requires that a minimum of 0.2 foot candles of illumination to be provided onto all floor area's during period of performances.

Some of the Requirements are as follows:

A: In assembly occupancies, the illumination of the floors of exit access shall be at least 0.2 ft-candle (2.2 lux) during periods of performances or projections involving directed light.

B: Changes in elevation must be clearly marked or indicated by a change in color.

C: Floor beveled extrusion must be ramped at a slope no steeper than 1.2 ratio, 1/2" Height, (i.e.) Floor extrusions must taper to 0 in a minimum of 1"

D: Emergency lighting is required throughout the path of egress and must operate for a min. of 90 minutes. Areas such as stairs, aisles, corridors, ramps, escalators, and passageways must be illuminated to an average of 1 foot candle with a min. of 0.1fc of light measured along the path of egress at floor level.

Let All Cinema Sales help you in the lighting design of your new facility or upgrade your current system to meet code. We have a comprehensive line of low voltage lighting products that will work in any application.